Titanium: The powerful new element in ESD floors for static control

 

22

Ti

4s23d2

 ElectraFloor Titanium T2

Elegant yet Powerful.

Titanium like wear resistance,

Outstanding electrical properties,

Unrivaled LEED and environmental sensitivity.

(printer and paper friendly)

 In stock, ready to ship!

 

While most esd flooring materials rely on mere conductive adhesives or a sprayed on grid work of carbon to maximize conductivity, Titanium features a full surface electrically conductive backing bonded to a hardened top surface wear layer to provide the ultimate in conductivity, wear resistance and resiliency. Titanium is provided in an eyes pleasing medium gloss for reduced glare, with a unique micro finishing technique that provides THE most slip resistant, easiest to clean, lowest maintenance vinyl on the market. Ti's FULLY clean room compliant and highly chemical resistant. Titanium's perfect for a multitude of applications including electronic assembly, munitions and pharmaceutical manufacturing.  It's a pure vinyl, devoid of cheap clay fillers, making it resilient and flexible (not brittle like most esd flooring). Hence, Titanium can be flash coved up walls and handles heavy loading without breaking. Utilizing our approved specialty conductive adhesives allows installation simply unheard in the past. When used in conjunction with our unique no residue VOC Free textile reinforced double sided adhesive, or our new United 2450 liquid conductive adhesive (voc free and CA proposition 65 compliant) Titanium can be installed over existing epoxy, VCT, non porous hard troweled concrete, painted surfaces, concrete and more. Your needs dictate: permanently bonded OR installed in a mode that allows removal and redeployment of the material in a different area! Titanium, the ultimate choice for clean rooms, electronic and sophisticated product development, manufacturing, command centers and more.  With specifications that meet or exceed the latest most stringent standards including the new  ANSI EOS ESD S 2020 2007,

 

Titanium T2

Tames the Static Beast before it can take another byte!

 

flash coved esd cleanroom flooring

Titanium esd flooring installed in clean room.  Flash coved up walls and heat welded for cleanliness.

 TV StaticFull surface static conductive backing. Ultimate conductivity.

 TV StaticWear resistant top layer. THE most wear resistant in the industry.
 TV Static Easily meets stringent NEW standards for optimum conductivity.

 TV StaticPermanent conductivity throughout, NOT humidity dependant.

 TV StaticAnti slip, anti scuff and clean room compliant.
 TV StaticEasy to keep clean, the lowest maintenance floor in the industry.
 TV StaticInstallation flexibility!  Can be installed over concrete, existing epoxy, VCT, even asbestos laden tiles! Unlike most esd flooring materials Ti is resilient and won't break, flake crumble or degrade.

 

Why Sheet goods? Titanium Series esd flooring is available in sheet goods (or optional tiles) for a very good reason. Let's look at a 150' x 60' area.  A typical 1' x 1' ESD tile will have over 18,000 linear feet (nearly 4 MILES of seams)! Take a look at this 3M esd TILE floor.  Bad tiles? Poor install? Not at all. Unfortunately tiles don't always fit perfectly and the installer must adjust (leave small spaces between the tiles) as the installation progresses (some tiles even shrink over a period of time). And / or the substrate isn't flat leaving an uneven profile (slight highs and lows) to the finished install.  Minute spaces between the tiles and  / or deviations in the flatness, a perfect environment for contaminant and dirt entrapment. On a standard tile floor these deviations typically present little problem, they are often filled in with floor wax. Esd floor finish shouldn't be a necessity for a quality esd floor.  It raises the insulative properties, can wreak havoc in a clean room (from powdering), is expensive and can be a maintenance application nightmare!

 

Titanium sheet goods, same area? less than 2,000 linear feet of seams and THESE seams are heat welded for the ultimate in cleanliness and ease of maintenance.

seamless esd floor

ESD Floor finish is not required for Titanium

 

Click samples below for 10 x magnification

Pale Gray

PN: Ti481

Dark Gray

PN: Ti482

Electronic Blue

PN: Ti483

Clean White

PN: Ti480

 


Short Form Performance Specifications:

 

ElectraFloor Titanium Series semi gloss permanently esd conductive solid vinyl industrial flooring product.  Roll goods may be used as mats or flooring. Titanium Series ESD Flooring is manufactured in the European Union for United ESD Incorporated, PO Box 19252, Colorado City CO 81019.  The material shall be manufactured as a co- extruded 4' 6" x 66' x .080 gauge sheet or 24" x 24" x .080 gauge tile with a hard wear resistant esd conductive top layer and a flexible full surface esd conductive supporting layer in a semi gloss finish.

 

Surface Resistivity Point to Point (PTP per EOS ESD S 7.1) >1.0E04 <1.0E06 (esd conductive)
Electrical Resistance to Ground (RTG per EOS ESD S 7.1) >1.0E04 <1.0E06 (esd conductive)
Flooring Radiant Panel: NFPA 253: Critical Radiant Flux 0.73 W/cm2, Class 1
Flooring Radiant Panel: NBSIR 75-950: Critical Radiant Flux Pass, Class 1
Flooring Radiant Panel: ASTM-648: Critical Radiant Flux 0.73 W/cm2, Class 1

Smoke Density, ASTM E-662; NFPA 258; Average optical density in burning / smoldering mode

<450
Residual Indentation LF-475A 0.002 average
Abrasive Wear, Taber H-18 wheel, 5,000 cycles, 1,000 gm weight 1.1% loss of weight
Abrasive Wear, Taber H-18 wheel, 1,000 gm weight to wear layer penetration (end point) >20,000 cycles, (2.0% loss of weight
Static coefficient of friction, ASTM D-2047-03, James Test average wet, dry leather .60 approx.
Static load limit DIN 16961.2 >1,000 P.S.I.
Charge decay time per FTMS 4046-101c < .17 seconds

 

 

Availability
Rolls: 4'6" x 66' x .080" gauge (297 SF per roll)
(1.4m x 20m x 2.0mm gauge)

Tiles: 24" x 24" x .080" gauge
(608 x 608mm x 2.0 mm gauge)

Weight
Rolls: 297 sft./roll = 185 lbs./roll (84 Kg/box)
Tiles: 15 tiles/box (60 sft.) = Weight/box 38 lbs. (18 Kg/box)

ESD Welding rod: 330 Linear feet per spool

 

ElectraFloor Titanium Series meets or exceeds the requirements of Federal Specifications LF-475a and SST-312b for flexibility, dimensional stability, resistance to reagents and residual indentation.

 

Meets latest standard of S2020:  ANSI/ESD STM97.1-2006

Resistance to ground in combination with Operator / Heel Grounders / ESD Flooring

 

TV StaticElectraFloor Titanium Series: A monolithic seamless solution to cleanliness, wear resistance and static control.

 

Titanium ESD Vinyl Flooring

Tames the Static Beast Before it Takes Another Byte!

 

 

United ESD

P.O.B. 19252, 4878 Lake View Circle

Colorado City, CO 81019

United States of America

 

Direct: 719.676.3928         Fax: 719.676.3929

 

24/7 Tech Support Hotline: (USA) 719.331.0656

 

 

Major Credit Cards Accepted

 

This site is protected by Copyright and Trademark laws

 under US and International law.  © 1993-2008 All rights Reserved

ESD Flooring,  Mats,  Chemicals,  ESD Ionizers, and Expertise

United ESD Tames the Static Beast BEFORE it Takes Another Byte

This page last updated on

05/13/2008