Installation and Specifications:
ST010 Wrist Strap Monitor
![]()
1. Mount the AEI-ST010 in a
convenient place on the workbench using the screws supplied with the
unit or the optional mounting bracket. The units are
frequently mounted on the underside of the workbench to keep them
out of the way.
2. Plug the power adaptor
into the ST-010 and into a grounded outlet. The LED should
turn red and the buzzer should sound. The ground in the outlet
is an important part of the system and should also be connected to
the ESD common point ground. The outlet and the common point
ground can be located at any convenient place on the workbench.
3. Plug a wrist strap into
the front of the unit and put it on. The OPERATOR LED should
turn green. If it doesn't, touch the wrist strap to the common
point ground. If the OPERATOR LED turns green then the wrist
strap was not making good contact with the Operators wrist.
Note: A calibration / test
unit is available for the ST-010. Simply plug the ground cable
into the common point ground and the operator cable into the
OPERATOR input. The LED should be red. It should be
Green when you press the "test" button.
|